Hydraulic Pump Diagnostics: How to Check Flow, Pressure and Efficiency
A pump doesn't create pressure, it creates flow. Once you understand that, it's easier to check whether a pump is worn. We show how to measure flow and efficiency, which sound and visual checks to do, and what to check before replacing the pump.

Table of contents (9)
When a machine loses power or slows down, the pump is usually the first suspect. Before you replace it, it's worth checking, because the cause is often elsewhere. Hydraulic pump diagnostics starts with understanding one simple rule and ends with measuring flow and efficiency. Here it is step by step.
The myth: a pump creates pressure #

This is one of the most common myths in hydraulics. In reality a pump creates flow, and pressure only appears when the oil meets resistance: a cylinder load, a valve or a restriction in the line.
The simplest example: if the pump's pressure line leads straight back to the tank, the oil flows freely and the gauge shows almost zero. The pump is working, there is flow, but no pressure. If you close that line with a valve, the oil has nowhere to go and pressure rises sharply until the relief valve opens.
The takeaway for diagnostics: low pressure doesn't always mean a weak pump. It can also be a wrongly set relief valve or a leak elsewhere in the system. That's why a pump is judged by its flow at working pressure.
How to measure pump flow #

A pump wears over time: clearances grow, some oil leaks internally from the outlet back to the inlet, and less of it reaches the system. This shows most clearly in a flow test. A flow meter, a pressure gauge and a loading valve are fitted on the pressure side, and the pump is gradually loaded with the valve.
- Run the pump at a known speed and note the flow with no load.
- Close the loading valve gradually and raise the pressure to working pressure.
- Read the flow at working pressure.
- Compare the result with the theoretical flow from the data sheet.
A healthy pump loses only a little flow at working pressure. A worn one loses noticeably more, and the higher the pressure, the bigger the loss. You can also see the drop in flow in the machine's work: cycles take longer and cylinders slow down under load.

Pump efficiency: how to calculate it #

Volumetric efficiency tells you what share of the theoretical flow actually reaches the system. You calculate theoretical flow from the pump displacement and speed, and read actual flow from the flow meter at working pressure.
Example: a 20 cm³/rev pump runs at 1,500 rpm. In theory it delivers 20 × 1,500 / 1,000 = 30 l/min. The flow meter shows 25.5 l/min at working pressure, so volumetric efficiency is 25.5 / 30 = 85%.
For pumps and hydraulic motors you also calculate hydraulic-mechanical efficiency: the theoretical torque from the data sheet is compared with the actual torque measured on a test rig. Overall efficiency is the product of the two.
What efficiency is too low? It depends on the pump type and manufacturer, so the thresholds on the graphic are only a guide. The most important thing is comparing with earlier measurements. If you check the pump regularly, you'll quickly see when it starts losing output and it's time to replace or rebuild it.
Symptoms and the most common causes of problems #

To notice that something is wrong, you need to know how the system works when everything is fine: how fast the cylinders move, what the oil temperature is and how the pump sounds. The most common problems are:
- loss of power: the machine can't cope with the work it was built for,
- overheating: a clogged cooler, leaks or a wrongly set relief valve that keeps sending oil back to the tank,
- air in the oil and cavitation,
- excessive pressure,
- contaminated oil and water in the oil,
- wrong oil viscosity or oil left too long without changing,
- normal wear of the pump, motor and other parts.
Sound check #

- Do you know the system's normal sound? Any change is a signal. Find out where it's coming from. Read more about where hydraulic system noise comes from.
- A high, steady whine or whistle is most often cavitation: the pump isn't getting enough oil at the inlet.
- A rattle like gravel or marbles inside, sometimes with a squeal, is usually air in the oil.
Visual check #

- Oil level: a low level often means a leak.
- Pump drive: is the drive motor running, is the PTO or clutch engaged? On some machines the pump drive is switched on separately.
- Pump shaft: is it turning? A sheared key or a damaged spline means no flow and loss of power.
- Oil appearance: foamy means air, cloudy and milky means water.
Checklist when you suspect the pump #

- is the pump getting oil: level, suction strainer and suction line,
- is the pump being driven: PTO, clutch, shaft, key,
- does the drive motor turn the right way (pump direction of rotation),
- is the suction line tight and not kinked,
- how is the relief valve set and is it stuck,
- are the control valve sections in the right position and are the coils and wiring connected.
Once you've found and fixed the cause, always test the system under load to make sure the problem is gone.
Thermal imaging: finding the hot spot #

Every internal leak turns energy into heat. Oil leaking through a worn valve, a cylinder piston seal or inside the pump heats up that particular component. A thermal imaging camera or an infrared thermometer lets you quickly find a spot that is clearly hotter than the rest of the system. It's a good lead for finding the cause of overheating and loss of power.
Pumps, motors and service at Frejus #
In our shop you'll find hydraulic pumps and motors, pump parts, control valves, valves and filters. We rebuild piston pumps in our own service workshop.
Does a hydraulic pump create pressure?
No. A pump creates flow. Pressure only appears when the oil meets resistance: a load, a valve or a restriction.
How do I check whether a hydraulic pump is worn?
Measure the flow at working pressure and compare it with the theoretical flow from the data sheet. The bigger the difference, the more worn the pump.
How do I calculate a pump's volumetric efficiency?
Divide the actual flow by the theoretical flow. Theoretical flow is displacement [cm³/rev] × speed [rpm] / 1,000 in l/min.
What is a thermal imaging camera useful for?
It shows a component that is clearly hotter than the rest of the system. That's often where oil is leaking internally.


"European Agricultural Fund for Rural Development: Europe investing in rural areas.” The operation entitled: “Support for the implementation of operations under the community-led local development strategy” under the measure ‘Support for local development under the LEADER initiative’” , aimed at the Development of the enterprise through investment in the construction of a storage hall, which will allow to increase employment and improve the economic performance of the enterprise, is co-financed by the European Union under the measure “Support for local development under the LEADER initiative” of the Rural Development Program 2014-2020